Metric evaluation error start – Get dynamic property error,Dynamic Category property error,Computation of a critical dynamic property failed. Retries Completed.

Hi all,
Getting this error? OMS 12.1.0.3?
Ok… After an investigation on MOS and also a SR opened with Oracle is was pointed to relation with Bug 17575631 CLUSTER DB HOME PAGE ERRORS- REGIONS FETCH REAL TIME DATA WILL NOT BE DISPLAYED on Database Plugin.
It’s solved in OMS 12.1.0.4 and also in 12.1.0.5.1 EM Database Plugin Bundle patch.

 I’ll show you how to workaround it. 🙂

Continue reading

Infiniband Error: Cable is present on Port “X” but it is polling for peer port

Facing this error? Let me guess: Ports 03, 05, 06, 08, 09 and 12 are alerting? You have a Quarter Rack? Have recently installed Exadata plugin to version 12.1.0.3 or higher?
Don’t panic!

This is probably related to Bug 15937297 : EM 12C HAS ERRORS CABLE IS PRESENT ON PORT ‘N’ BUT IT IS POLLING FOR PEER PORT. The full message might be like “Cable is present on Port 6 but it is polling for peer port. This could happen when the peer port is unplugged/disabled“.

In fact, the bug was closed as not a bug. 🙂
As part of the 12.1.0.3 Exadata plugin, the IB switch ports are now checked for non-terminated cables. So these errors ‘polling for peer port’ are the expected behavior.  Once ‘polling for peer port’ is an enhanced feature of the 12.1.0.3 plugin, this explains why you most likely did not see these errors until you upgraded the OMS to 12.1.0.2 and then updated the plugins.

In Quarter Racks, the following ports 3, 5, 6, 8, 9 and 12 are usually cabled ahead of time, but not terminated. In some racks port 32 may also be unterminated. Checking for incident in OEM you might see something like this image:

newscreenshot-2016-12-26-as-20-03-50

Continue reading